Quick answer
A bolt torque pattern sets the order for tightening flange bolts so the gasket compresses evenly. The common method is a star or cross sequence. Each bolt is followed by one on the opposite side, over several passes at rising torque, then a circular check pass. Component Solutions Group (CSG) supplies the traceable fasteners these joints depend on.
Tighten a flange in a simple circle and one side of the gasket loads first, leaving uneven compression, leak paths, gasket extrusion or blowout, and rework. Each new bolt also relaxes the bolts already tightened: Bolt Science measured preload reductions as high as 35 percent from this effect, and HYTORC cites research showing a 10 to 30 percent preload loss per pass in adjacent fasteners.
How CSG Supplies This
Component Solutions Group (CSG) is an industrial fastener distributor and supply-chain partner for OEMs. CSG is based in Dayton, Ohio. It is a Bufab company and sources through the Bufab network of 1,600+ suppliers in 30+ countries.
CSG is an authorized source for BUMAX, Böllhoff (HeliCoil), HellermannTyton, ITW Nexus, Sherex and Southco. OEM programs include vendor managed inventory (VMI), consignment, kitting, C-parts management and design-assist engineering.
CSG holds ISO 9001:2015 and AS9120 Rev B and is ITAR registered. CSG’s Automotive and Tier 1 division (A1) is IATF 16949 certified. The company runs a 99.9 percent order accuracy rate. Before a flange goes to assembly, engineers set baseline clamp load targets with the torque and preload calculator.
What Goes Wrong on a Gasketed Flange: Extrusion and Preload Loss
Tightening a bolt compresses the flange and gasket under it. That compression relaxes the bolts already tightened nearby. Engineers call this elastic interaction.
With a simple circular order, the first bolts have lost preload by the time the last bolts reach target. The gasket ends up crushed on one side and underloaded on the other. The HYTORC figure is a loss per pass, which is why one trip around the flange is not enough.
That uneven load shows up as five specific failures:
- Gasket extrusion or blowout. The overloaded side crushes or pushes out the gasket, and the underloaded side leaves it free to move under pressure.
- Leaks and fugitive emissions. An unevenly seated gasket opens a leak path, and process fluid or vapor escapes at the joint.
- Rework and unplanned downtime. A flange that leaks on test or startup has to be depressurized, broken apart and reassembled, often with a new gasket.
- Torque that does not equal clamp load. Friction changes with lubrication and finish, so the same wrench setting gives different preload from bolt to bolt.
- Crew error. Skipped bolts, lost counts and out-of-order passes undo the pattern, which is why every bolt gets a number before any load goes on.
A star or cross pattern counters the first three. Consecutive bolts sit on opposite sides of the flange, so the faces close parallel. The preload loss spreads across the whole joint instead of building up in one spot. Confirm final assembly values against the governing standard, such as ASME PCC-1, or the gasket maker’s technical data.
The Star Pattern Tightening Sequence
A star pattern gives each bolt a number, and consecutive numbers fall on alternating sides of the flange. The crew then tightens in numeral order. No single official number string exists for any bolt count.
Inertech and the UK Defence Infrastructure Organisation (DIO), in Technical Bulletin 2022-03, each publish their own numbered diagonal layouts. Both are valid, and both follow the same rule: alternate sides.
The flange bolt torque sequence chart below shows one way to work the pattern. Bolt positions are numbered clockwise from the top. In the 4, 8 and 16 bolt orders, every second bolt sits directly across from the one before it. The 12 bolt order works in groups of three bolts spaced 120 degrees apart.
| Bolt Count | Example Tightening Order (positions numbered clockwise) |
|---|---|
| 4 bolts | 1, 3, 2, 4 |
| 8 bolts | 1, 5, 3, 7, 2, 6, 4, 8 |
| 12 bolts | 1, 5, 9, 3, 7, 11, 2, 6, 10, 4, 8, 12 |
| 16 bolts | 1, 9, 5, 13, 3, 11, 7, 15, 2, 10, 6, 14, 4, 12, 8, 16 |
A 20 bolt flange follows the same logic. Pick a bolt and go straight across. Then rotate a quarter turn, go across again, and work through the remaining positions in opposite pairs.
What Is an 8 Bolt Torque Pattern?
An 8 bolt torque pattern applies the crossing rule to an eight-hole flange. Start at the top bolt and go to the bottom. Shift 90 degrees to the right, then cross to the left.
The last four bolts split the gaps between the first four, again in opposite pairs. With positions numbered clockwise, the order reads 1, 5, 3, 7, 2, 6, 4, 8. Run the same order on every star pass. Before specifying hardware, check hole spacing with the bolt circle calculator.
Torque Sequence for 16 Bolts and Beyond
A large flange has more bolts, so there are more tightening steps where elastic interaction shifts preload. A torque sequence for 16 bolts follows the same rule. Bolts 1 and 9 sit across from each other, 5 and 13 sit a quarter turn away, and 3, 11, 7 and 15 split the quadrants. The last eight bolts fill the remaining gaps in opposite pairs.
On a 16, 20 or 24 bolt flange, mark the number on each stud or on the flange face before applying any load. The marks keep the crew on sequence through every pass. To see how torque relates to clamp load, read CSG’s torque calculator guide before assembly.
How Many Torquing Passes Are Used?
One trip through the star pattern does not overcome elastic interaction. Flange assembly uses several passes at rising torque.
For ASME PCC-1 style work, HYTORC reports an assembly pass to about 20 percent of target torque. Next come passes at roughly 20 to 30 percent, 50 to 70 percent and 100 percent, all in the star pattern. A final check pass then runs circularly at 100 percent to verify every bolt.
UK DIO Technical Bulletin 2022-03 is similar. It calls for numbered passes at 30, 60 and 100 percent, then a rotational 100 percent pass. That rotational pass is repeated after about four hours of rest.
| Step | HYTORC (PCC-1 Style) | UK DIO TB 2022-03 |
|---|---|---|
| Star or numbered passes | About 20% assembly pass, then 20% to 30%, 50% to 70% and 100% | 30%, 60% and 100% |
| Check pass | 100%, circular, until no bolt moves further | 100%, rotational |
| Repeat after rest | Not part of the reported sequence | 100% rotational pass after about 4 hours |
Spiral Patterns for Non-Circular Joints
Not every joint is a round flange. Rectangular covers, gearbox housings and other non-circular bolt patterns also need a set tightening order.
For a non-circular bolt pattern, Mountz calls for a spiral that starts at the middle bolt and works outward. The rule applies to any multi-bolt joint, not only flanges. For grade limits on these joints, the grade 8 bolt torque chart is a starting reference.
Manual Torque Wrenches vs Hydraulic Tensioners
ASME PCC-1, the guideline for pressure boundary bolted joint assembly, outlines alternative tightening procedures in its Appendix F. Flange size and access around the joint drive the choice.
A torque wrench turns the nut against heavy friction. Enerpac puts only about 10 to 15 percent of input torque into actually stretching the bolt. Friction changes with lubrication and finish, so check the nut factor with the nut factor accuracy calculator before you set torque.
Hydraulic wrenches and tensioners suit larger flanges. A tensioner pulls the stud directly to stretch it, . Tensioning does not remove elastic interaction entirely, . Sequence and passes still apply. For stud and nut selection, see CSG’s guide to flange bolts.
Lock In the Pattern, Passes and Tooling Before the First Bolt Turns
Start with joint geometry. A round flange takes a star or cross pattern. A non-circular joint takes a spiral from the middle bolt.
Next, write the passes into the procedure, including the circular check pass after the star passes, and number every bolt on the flange face. Then pick tooling that fits the clearance around the flange and applies load the same way every time. A written sequence takes minutes. A leaking flange means breaking the joint, fitting a new gasket and assembling it a second time.
Component Solutions Group supplies OEMs with traceable fasteners for sealed and critical joints. To source studs, nuts and washers for your next flange program, contact our OEM team through the RFQ form.
Frequently Asked Questions (FAQs)
What standards govern flange bolt torque patterns?
ASME PCC-1 is the main US guideline for assembling pressure-boundary bolted flange joints. It covers tightening patterns, multi-pass loading and the recognized ways to load the bolts. Other owners publish their own procedures, such as UK DIO Technical Bulletin 2022-03, and the gasket maker’s data sets the target load.
How do you number bolts for a cross pattern?
Number the bolts so consecutive numbers sit on opposite sides of the flange. Assign 1, jump 180 degrees for 2, move 90 degrees for 3, then jump 180 degrees again for 4. Continue in opposite pairs until every bolt has a number, then tighten in numeral order.
What is elastic interaction in a bolted joint?
Elastic interaction happens when tightening one bolt compresses the joint material around it. That compression relaxes the tension in nearby bolts that were already tightened. The result is a loss of the clamp load those bolts started with.
How do I calculate the correct torque for my flange bolts?
Start with the clamp load the gasket needs, taken from the governing standard or the gasket maker’s data. Convert that load to torque using the bolt diameter and a nut factor for thread and bearing friction. CSG’s torque and preload calculator runs the conversion. Recheck it whenever lubrication or finish changes, because the same torque then gives a different clamp load.
Do hydraulic tensioners eliminate the need for a tightening sequence?
No. Tensioners stretch the stud directly and bypass thread friction, but the joint still sees elastic interaction. Multiple passes in a set sequence are still required for even gasket compression.
Why is a circular check pass used after a star pattern?
The check pass confirms every bolt held its target load after the star passes. The crew moves around the flange in order at 100 percent torque until no bolt turns further. It catches any bolt that relaxed during the earlier passes.