Quick answer
A stud bolt is a headless fastener, threaded along its full length or at both ends, that clamps a joint with nuts instead of a bolt head. Flanges use studs because they load the gasket evenly. Component Solutions Group (CSG) sources continuous thread, tap end and double end studs in ASTM A193 and A320 grades.
Flange joints in process piping leak when clamp force goes uneven, and studs that gall in hot service turn a routine turnaround into a cutting job. ASTM A193 caps B7M studs at 235 HB, against 321 HB for standard B7, so the grade matters as much as the stud’s form, and that gap is why B7M goes into sour service.
How CSG Supplies This
Component Solutions Group is an industrial fastener distributor and supply-chain partner for OEMs, based in Dayton, Ohio. As a Bufab Group company, CSG draws on a network of 1,600+ suppliers in 30+ countries.
Services include vendor managed inventory, consignment, kitting, C-parts management, design-assist engineering and global sourcing. CSG is an authorized source for BUMAX, Böllhoff (HeliCoil), HellermannTyton, ITW Nexus, Sherex and Southco, with a 99.9% order accuracy rate.
CSG holds ISO 9001:2015 and AS9120 Rev B and is ITAR registered. Its Automotive & Tier 1 division (A1) is IATF 16949 certified. CSG’s design-assist engineering team helps match the right grade and nut pairing to your joint.
Overcoming Joint Failures in High-Pressure Environments
Process piping and pressure vessels run through constant thermal cycles and mechanical load. Uneven clamp force across a flange leads to slow leaks or a blown gasket.
Hex head bolts are tightened from one side, so tension across a large flange face is harder to keep even. Studs that gall or corrode in hot chemical service seize at turnaround, and crews end up cutting them out instead of backing the nuts off.
The fix is traceable, grade-specific studs matched to the joint.
What Is a Stud Bolt and Why Do Flanges Need Them?
A stud bolt has no head. It is threaded at both ends or along its full length, and nuts do the clamping. That setup makes studs the default for flanged joints in petrochemical, power generation and heavy industrial plants.
Flanges use studs instead of hex head bolts for three reasons:
- Even load. Nuts on both sides let the stud stretch evenly, which spreads clamp force across the gasket.
- Full thread engagement. Each nut sits on full threads, which matters under high pressure and temperature.
- Easier removal. If threads seize, crews cut the stud and pull it without damaging the flange.
Shape does not set strength. A stud is not stronger than a hex bolt of the same grade, because material and heat treatment set the strength. Confirm mechanical values against the governing standard or the maker’s data sheet.
A stud bolt is tightened with nuts and is not welded, which makes it different from a weld stud welded directly to a base metal.
Types of Stud Bolts: Continuous, Tap End, and Double End
Stud bolts come in three common forms. Makers sometimes use “tap end” and “double end” almost interchangeably, so check the drawing, not just the name.
Continuous Thread Studs
These are threaded end to end. They are the standard choice for flange bolting with a nut on each side.
A continuous thread stud is not the same as general-purpose threaded rod. The stud comes in a pressure-service grade such as A193 B7, with chamfered ends and a material test report. Commodity threaded rod is usually low-carbon steel with no pressure rating, and it does not belong in a process flange.
Tap End Studs
A short thread on one end goes into a tapped hole, and the longer end takes a nut. The stud stays seated in the hole when crews remove the nut for maintenance.
Double End Studs
These carry equal thread lengths on both ends with an unthreaded shank between. Engineers specify double end threaded studs for pipe flanges when they want a set thread length at each nut.
ASTM A193 and A320 Material Grades
The grade decides whether a joint holds pressure or yields under heat. ASTM A193 covers alloy and stainless studs for high-temperature or high-pressure service, and ASTM A320 Our ASTM A193 vs A320 guide compares B7, B16 and L7 by service temperature.
Heat treatment sets strength and yield point. Quenching locks in hardness, and tempering reheats the steel to trade some hardness for ductility. For how B7 compares with structural and SAE grades, see our bolt grade comparison.
A193 B7 is the standard alloy steel stud for process piping flanges. It is quenched and tempered chromium-molybdenum steel, used to about 750°F.
A193 B7M shares B7 chemistry but gets a different heat treatment. Its maximum hardness is 235 HB, against 321 HB for B7. That lower hardness resists sulfide stress cracking in sour H2S service.
A193 B8 and B8M are austenitic stainless studs. B8 uses a 304 base, and B8M uses 316 for better chloride resistance.
A320 L7 shares B7 chemistry and adds mandatory Charpy V-notch impact testing at minus 150°F, with a 20 ft-lb minimum. That test qualifies it for low-temperature service.
| ASTM Grade | Material | Key Characteristics | Typical Application |
|---|---|---|---|
| A193 B7 | Chromium-molybdenum steel | Quenched and tempered, 321 HB max | Standard process piping, to about 750°F |
| A193 B7M | Chromium-molybdenum steel | Lower max hardness, 235 HB | Sour H2S service |
| A193 B8 / B8M | Austenitic stainless (304 / 316) | Corrosion resistant, B8M for chlorides | Chemical and chloride exposure |
| A320 L7 | Chromium-molybdenum steel | Charpy V-notch tested at minus 150°F | Low-temperature service |
Matching the Right Nuts to Your Stud Bolts
A high-strength stud needs a nut to match. ASTM A194 covers the heavy hex nuts used with high-pressure studs.
Pair A193 B7 studs with A194 2H nuts. Grade 2H is quenched and tempered carbon steel with an 850°F minimum tempering temperature. For sour service, pair B7M studs with A194 2HM nuts, not 2H, so the whole assembly keeps the lower hardness.
How to Calculate Stud Bolt Length and Torque
Measure stud length parallel to the axis, excluding the chamfered points, and build it from flange thickness, nut height, washers, the gasket and thread stick-out past each nut. For ASME B16.5 flanges, the standard’s dimension tables list stud length by flange size and pressure class.
Torque relates to preload through a nut factor for thread and bearing friction, so one torque value gives different clamp loads with different lubricants. A single number from a bolt torque chart won’t fit every joint. Run your joint through the torque and preload calculator, and see our flange bolts guide for flange sizing and tightening detail.
Coatings and Friction Factors
Coatings protect the steel and make friction more predictable. Bare steel runs a friction factor of about 0.20, while PTFE or Xylan coatings bring it down to roughly 0.10 to 0.12. That tighter range makes preload calculations more reliable.
Hot-dip galvanizing is the other common option. It lays down about 1.7 to 3.4 mils of zinc, with a coating bond strength around 3,600 psi. Nuts are tapped oversize after galvanizing to fit the thicker coating.
Skip hot-dip galvanizing on fasteners above 150 ksi tensile strength. At that strength, galvanizing brings a real risk of hydrogen embrittlement and sudden failure under load.
Which Stud and Nut Pairing Fits Your Joint?
Pick the stud grade from operating temperature and chemical exposure first. Then match the nut to the stud’s hardness, and calculate preload with the friction factor of the coating or lubricant you actually use.
- Standard process piping: A193 B7 studs with A194 2H nuts.
- Sour H2S service: A193 B7M studs with A194 2HM nuts.
- Corrosive or chloride exposure: A193 B8 or B8M stainless.
- Low-temperature service: A320 L7, impact tested at minus 150°F.
- Premium stainless: BUMAX stud bolts where the joint needs both corrosion resistance and strength.
Before you order, write down the flange class, service temperature, process media and coating, and require a material test report for every lot. With those four inputs fixed, the grade, nut and preload follow.
Need traceable studs and nuts for your next flange job? Submit an RFQ with those details, and the CSG team will source the exact grades your application calls for.
Frequently Asked Questions (FAQs)
Is a stud bolt stronger than a hex bolt?
No. A stud and a hex bolt of the same grade have the same material strength, because grade and heat treatment set strength, not shape. Studs win on flanges because they load the joint more evenly.
Can I substitute a hex bolt for a stud bolt on a high-pressure flange?
It’s a poor trade. Studs tightened from both sides give more even load and full thread engagement. Hex bolts load from one side and are hard to remove once threads gall or corrode in service.
What is the difference between a stud bolt and a threaded rod?
A continuous thread stud is made to a pressure-service grade such as ASTM A193 B7, cut to length with chamfered ends and supplied with a material test report. General-purpose threaded rod is usually low-carbon steel with no pressure rating. Don’t substitute it on a pressure vessel or process flange.
What makes A193 B7M different from A193 B7?
Both grades share the same chromium-molybdenum chemistry. B7M gets a different heat treatment that caps hardness at 235 HB, against 321 HB for B7. That lower hardness resists sulfide stress cracking in sour H2S service.
When should you use A320 L7 studs?
Use L7 for low-temperature service. It shares B7 chemistry but must pass Charpy V-notch impact testing at minus 150°F with a 20 ft-lb minimum, which standard B7 does not require.
How do you calculate stud bolt length for ASME flanges?